The IZOPROOF® ALu insulation boards comprise of a PIR rigid foam thermal insulation core. The boards are protected on both sides gas-tight aluminum foil lining with a thickness of 50 μm. A board intended for insulating flat roofs in glued and mechanical systems.

  • Technical data
  • Joint types
  • Logistics: 1200 mm x 600 mm
  • Logistics: 1200 mm x 2400 mm
  • Certificates
1
Kind of core:
Rigid polyisocyanurate foam(PIR)
2
Density [kg/m3]:
p = 30 kg/m3
3
Declared heat transfer coefficient for lining λ:
λD = 0,022​​
4
Type of facing:
Double-sided cladding consisting of 50 micron aluminum.
5
Standard board dimensions [mm]:
600 x 1200 ; 1200 x 2400​​
6
Available boards dimensions [mm]:
1000 x 1200 ; 1200 x 1200 ; 1800 x 1200 ; 1200 x 3000​​
7
Joint types*:
FIT - flat milling, LAP - stepwise milling, TAG - tongue and groove
8
Board thicknesses available:
from 20 to 250 mm
9
Board thickness [mm]:
20 30 40 50 60 70 80 90 100 110 120 130
10
Thermal resistance RD:
0,90 1,35 1,85 2,30 2,75 3,25 3,70 4,15 4,65 5,10 5,55 6,05
11
Heat transfer coefficient U for roof:
0,96 0,67 0,50 0,41 0,35 0,29 0,26 0,23 0,21 0,19 0,18 0,16
12
Board thickness [mm]:
140 150 160 170 180 190 200 210 220 230 240 250
13
Thermal resistance RD:
6,50 6,95 7,45 7,90 8,35 8,85 9,30 9,75 10,2 10,7 11,1 11,6
14
Heat transfer coefficient U for roof:
0,15 0,14 0,13 0,12 0,12 0,11 0,11 0,10 0,10 0,09 0,09 0,08
15
Reaction to fire (single board):
20-49: F class, 50-250: E class
20
Reaction to fire (in the system):
B-s2,d0 (trapezoidal sheet)
21
Broof(t1) / NRO :
Broof(t1) (mechanism gluing)
22
Fire resistance:
REI 30

Milled edges facilitate assembly and increase thermal insulation.

The termPIR<sup>®</sup> insulation boards

Joint types:
01. FIT (flat milling from 20-250 mm), 02. LAP (stepwise milling from 40-250 mm)*, 03. TAG (tongue and groove from 40-250 mm)*

* dimensions of boards with joint types are 2 to 4 % smaller

Loading and Unloading is carried out manually by single packages or using a fork lift provided with a grab for some packages. In case of longer, not typical panels, the relevant equipment or more persons should be provided for unnloading. In this way, panel breaking or damage can be prevented.

Note!
Boards are prone to damage, also when they are in the packaging. It is not allowed to throw or roll the packages. The transport of thermal insulation boards should be executed by trucks intended for this purpose. Upon the reception of insulation boards, the number and quality of the delivered commodities should be checked. Discrepancies should be described in the shipping list and reported to the manufacture immediately. Possible damage to boards on the truck should be documented with photographs.

Storage recommendations

  • packagesshould be stored in a dry place; they should not be put directly on the ground, but supports should be used,
  • do not place heavy objects on the panels, this can cause serious damage,
  • protect from weather conditions,
  • single boards should be transported vertically so as to avoid their breaking.

termPIR® thermal insulation boards are packed in packages enabling their handling. The typical package height is 500 mm.The number of panels depends on its thickness.

In the table belowe are the basic logistics parameters of termPIR® products. Detailed information has been included in the LOGISTICS CARDS.

1
Covering area of one board [m²]:
0,72 m²
2
Board dimensions:
1200 mm x 600 mm
3
Packing method:
Packages packed in stacks:
4
Board thickness [mm]:
20 30 40 50 60 70 80 90 100 110 120 130
5
Number of boards in a package:
24 16 12 10 10 7 6 6 5 5 5 4
6
Number of packages in a stack:
10 10 10 10 8 10 10 8 10 8 8 8
7
Board thickness [mm]:
140 150 160 170 180 190 200 210 220 230 240 250
8
Number of boards in a package:
4 4 3 3 3 3 3 2 2 2 2 2
9
Number of packages in a stack:
8 8 8 8 8 8 8 10 10 10 10 10

Loading and Unloading is carried out manually by single packages or using a fork lift provided with a grab for some packages. In case of longer, not typical panels, the relevant equipment or more persons should be provided for unnloading. In this way, panel breaking or damage can be prevented.

Note!
Boards are prone to damage, also when they are in the packaging. It is not allowed to throw or roll the packages. The transport of thermal insulation boards should be executed by trucks intended for this purpose. Upon the reception of insulation boards, the number and quality of the delivered commodities should be checked. Discrepancies should be described in the shipping list and reported to the manufacture immediately. Possible damage to boards on the truck should be documented with photographs.

Storage recommendations

  • packagesshould be stored in a dry place; they should not be put directly on the ground, but supports should be used,
  • do not place heavy objects on the panels, this can cause serious damage,
  • protect from weather conditions,
  • single boards should be transported vertically so as to avoid their breaking.

termPIR® thermal insulation boards are packed in packages enabling their handling. The typical package height is 500 mm.The number of panels depends on its thickness.

In the table belowe are the basic logistics parameters of termPIR® products. Detailed information has been included in the LOGISTICS CARDS.

1
Covering area of one board [m²]:
2,88 m²
2
Board dimensions:
1200 mm x 2400 mm
3
Packing method:
Packages packed in stacks:
4
Board thickness [mm]:
20 30 40 50 60 70 80 90 100 110 120 130
5
Number of boards in a package:
24 16 12 10 10 7 6 6 5 5 5 4
6
Number of packages in a stack:
5 5 5 5 4 5 5 4 5 4 4 4
7
Board thickness [mm]:
140 150 160 170 180 190 200 210 220 230 240 250
8
Number of boards in a package:
4 4 3 3 3 3 3 2 2 2 2 2
9
Number of packages in a stack:
4 4 5 4 4 4 5 5 5 5 5 5
1
Quality mark:
CE
2
System certificates:
ISO 9001, ISO 14001
3
Compliance with:
EN 13165+A2 oraz EN 13172
4
Tests of thermal properties:
ITB
5
Authorized to trading within the:
UE

Why is it worth?

The termPIR<sup>®</sup> insulation boards
Resistance to biological and chemical factors

You don't have to share the house with rodents and insects, or worry about fungi or mold.

The termPIR<sup>®</sup> insulation boards
Fire resistance

They don't keep the fire burning.

The termPIR<sup>®</sup> insulation boards
Easy assembly

You don't need a specialist for assembly.

The termPIR<sup>®</sup> insulation boards
High water resistance - water absorption below 2%

They can be installed almost all year round because they do not absorb water.